ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2017, Volume 68, Issue 5, 1130-1136

https://doi.org/10.37358/RC.17.5.5627

Ademir Horia Stana, Otilia Lavinia Stana (Gag), Gheorghe Ciobanu, Anca Porumb, Calin Gheorghe Cioban, Ramona Amina Popovici, Alexandra Moga

Applications of Imaging Technologies in Maxillary Cyst Assessment

Abstract:

The use of dental radiographies is nowadays indispensible for the clinician, and the evolution of x-rays provide quality images of the anatomic structures. The indications for a radiographic exam must be based on a clinical examination of the patient. Although the most used radiographies in dentistry are the retroalveolar and the panoramic one, it is considered that the indication for a CBCT scanning should be professional justified and evaluated as a balance between the benefits and the risk of exposure at radiation. The CBCT scans provide good quality images of the anatomic structures, with an accurate delimitation of the pathologic lesions, fact that allows the practitioner to proper evaluate the surrounding structures. CBCT technique uses an x-ray beam shaped like a cone that records 3D images in a single gantry rotation (360 degrees) within 6-20 seconds, with a radiation dose that depends on several factors. The comparison of the radiation dose of the CBCT (11-674 mSv) and the panoramic radiography (2.7-24.3 mSv) demonstrates that the CBCT requires a higher dose of radiation, but the high image quality is competing with the ones obtained with MSCT (280-1,410 mSv). The panoramic radiography uses an x-ray beam that is angled at aproximately 8 degrees, providing the practitioner a 2D radiographic image of the anatomic structures. The disadvantages of the panoramic radiography are the overlapping of the anatomic structures, the distortion and the blurry image. The study is based on the measurements of cystic lesions of the mandibular and maxillary bone that were present on radiographies and CBCT scans of 25 patients. The result of the measurements was that significative differences were found between the panoramic image of the cyst and the reconstructive image that the CBCT.
Keywords:
dental radiographies; CBCT;X-ray

Issue: 2017, Volume 68, Issue 5
Pages: 1130-1136
Publication date: 2017/6/15
https://doi.org/10.37358/RC.17.5.5627
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
STANA, A.H., STANA (GAG), O.L., CIOBANU, G., PORUMB, A., CIOBAN, C.G., POPOVICI, R.A., MOGA, A., Applications of Imaging Technologies in Maxillary Cyst Assessment, Rev. Chim., 68(5), 2017, 1130-1136.

Vancouver
Stana AH, Stana (Gag) OL, Ciobanu G, Porumb A, Cioban CG, Popovici RA, Moga A. Applications of Imaging Technologies in Maxillary Cyst Assessment. Rev. Chim.[internet]. 2017 May;68(5):1130-1136. Available from: https://doi.org/10.37358/RC.17.5.5627


APA 6th edition
Stana, A.H., Stana (Gag), O.L., Ciobanu, G., Porumb, A., Cioban, C.G., Popovici, R.A. & Moga, A. (2017). Applications of Imaging Technologies in Maxillary Cyst Assessment. Revista de Chimie, 68(5), 1130-1136. https://doi.org/10.37358/RC.17.5.5627


Harvard
Stana, A.H., Stana (Gag), O.L., Ciobanu, G., Porumb, A., Cioban, C.G., Popovici, R.A., Moga, A. (2017). 'Applications of Imaging Technologies in Maxillary Cyst Assessment', Revista de Chimie, 68(5), pp. 1130-1136. https://doi.org/10.37358/RC.17.5.5627


IEEE
A.H. Stana, O.L. Stana(Gag), G. Ciobanu, A. Porumb, C.G. Cioban, R.A. Popovici, A. Moga, "Applications of Imaging Technologies in Maxillary Cyst Assessment". Revista de Chimie, vol. 68, no. 5, pp. 1130-1136, 2017. [online]. https://doi.org/10.37358/RC.17.5.5627


Text
Ademir Horia Stana, Otilia Lavinia Stana(Gag), Gheorghe Ciobanu, Anca Porumb, Calin Gheorghe Cioban, Ramona Amina Popovici, Alexandra Moga,
Applications of Imaging Technologies in Maxillary Cyst Assessment,
Revista de Chimie,
Volume 68, Issue 5,
2017,
Pages 1130-1136,
ISSN 2668-8212,
https://doi.org/10.37358/RC.17.5.5627.
(https://revistadechimie.ro/Articles.asp?ID=5627)
Keywords: dental radiographies; CBCT;X-ray


RIS
TY - JOUR
T1 - Applications of Imaging Technologies in Maxillary Cyst Assessment
A1 - Stana, Ademir Horia
A2 - Stana (Gag), Otilia Lavinia
A3 - Ciobanu, Gheorghe
A4 - Porumb, Anca
A5 - Cioban, Calin Gheorghe
A6 - Popovici, Ramona Amina
A7 - Moga, Alexandra
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2017
VL - 68
IS - 5
SP - 1130
EP - 1136
UR - https://doi.org/10.37358/RC.17.5.5627
KW - dental radiographies
KW - CBCT
KW - X-ray
ER -


BibTex
@article{RevCh2017P1130,
author = {Stana Ademir Horia and Stana (Gag) Otilia Lavinia and Ciobanu Gheorghe and Porumb Anca and Cioban Calin Gheorghe and Popovici Ramona Amina and Moga Alexandra},
title = {Applications of Imaging Technologies in Maxillary Cyst Assessment},
journal = {Revista de Chimie},
volume = {68},
number = {5},
pages = {1130-1136},
year = {2017},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.17.5.5627},
url = {https://revistadechimie.ro/Articles.asp?ID=5627}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice