ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2018, Volume 69, Issue 3, 660-664

https://doi.org/10.37358/RC.18.3.6170

Ionut Daniel Mihai, Roxana Mihai, Claudiu Vartolomei, Raluca Monica Comaneanu, Stefania Coman, Doina Lucia Ghergic

Study About the Precision of Surgical Guides Used in Implantology

Abstract:

The purpose of this study was to detect the precision of inserting dental implants using 3 types of surgical guides on 3 groups of patients according to the degree of implantologist experience. In this study, 27 patients were taken, in 3 groups of 9 patients, who addressed to dental offices in which were implantologists with 1 year (group A), 6 years (group B) and 11 years (group C) of experience in surgery. Lot A, operated by a 1-year physician with experience in implantology, had the smallest deviation, demonstrating the increased attention that he had to the interventions. Comparing B and C lots, the smallest deviations were recorded for group C, operated by implantologist with greater experience in implantology. By comparing the deviations according to the type of surgical guide used, the smallest deviations at the apex and prosthetic platform were made in patients where the implants were inserted with a bone supported guide, followed by dental-gingival and mucosal guide. In terms of axis of implantation, the lowest values were recorded for the dental-gingival guide, followed by the bone and mucosal guide. The study has a number of limitations (low number of patients undergoing study, low dispensation period), which requires more extensive future studies to validate the results.
Keywords:
dental implant; surgical guide; CBCT; SimPlant®

Issue: 2018, Volume 69, Issue 3
Pages: 660-664
Publication date: 2018/4/15
https://doi.org/10.37358/RC.18.3.6170
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
MIHAI, I.D., MIHAI, R., VARTOLOMEI, C., COMANEANU, R.M., COMAN, S., GHERGIC, D.L., Study About the Precision of Surgical Guides Used in Implantology, Rev. Chim., 69(3), 2018, 660-664.

Vancouver
Mihai ID, Mihai R, Vartolomei C, Comaneanu RM, Coman S, Ghergic DL. Study About the Precision of Surgical Guides Used in Implantology. Rev. Chim.[internet]. 2018 Mar;69(3):660-664. Available from: https://doi.org/10.37358/RC.18.3.6170


APA 6th edition
Mihai, I.D., Mihai, R., Vartolomei, C., Comaneanu, R.M., Coman, S. & Ghergic, D.L. (2018). Study About the Precision of Surgical Guides Used in Implantology. Revista de Chimie, 69(3), 660-664. https://doi.org/10.37358/RC.18.3.6170


Harvard
Mihai, I.D., Mihai, R., Vartolomei, C., Comaneanu, R.M., Coman, S., Ghergic, D.L. (2018). 'Study About the Precision of Surgical Guides Used in Implantology', Revista de Chimie, 69(3), pp. 660-664. https://doi.org/10.37358/RC.18.3.6170


IEEE
I.D. Mihai, R. Mihai, C. Vartolomei, R.M. Comaneanu, S. Coman, D.L. Ghergic, "Study About the Precision of Surgical Guides Used in Implantology". Revista de Chimie, vol. 69, no. 3, pp. 660-664, 2018. [online]. https://doi.org/10.37358/RC.18.3.6170


Text
Ionut Daniel Mihai, Roxana Mihai, Claudiu Vartolomei, Raluca Monica Comaneanu, Stefania Coman, Doina Lucia Ghergic,
Study About the Precision of Surgical Guides Used in Implantology,
Revista de Chimie,
Volume 69, Issue 3,
2018,
Pages 660-664,
ISSN 2668-8212,
https://doi.org/10.37358/RC.18.3.6170.
(https://revistadechimie.ro/Articles.asp?ID=6170)
Keywords: dental implant; surgical guide; CBCT; SimPlant®


RIS
TY - JOUR
T1 - Study About the Precision of Surgical Guides Used in Implantology
A1 - Mihai, Ionut Daniel
A2 - Mihai, Roxana
A3 - Vartolomei, Claudiu
A4 - Comaneanu, Raluca Monica
A5 - Coman, Stefania
A6 - Ghergic, Doina Lucia
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2018
VL - 69
IS - 3
SP - 660
EP - 664
UR - https://doi.org/10.37358/RC.18.3.6170
KW - dental implant
KW - surgical guide
KW - CBCT
KW - SimPlant®
ER -


BibTex
@article{RevCh2018P660,
author = {Mihai Ionut Daniel and Mihai Roxana and Vartolomei Claudiu and Comaneanu Raluca Monica and Coman Stefania and Ghergic Doina Lucia},
title = {Study About the Precision of Surgical Guides Used in Implantology},
journal = {Revista de Chimie},
volume = {69},
number = {3},
pages = {660-664},
year = {2018},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.18.3.6170},
url = {https://revistadechimie.ro/Articles.asp?ID=6170}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice