ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2018, Volume 69, Issue 10, 2858-2862

https://doi.org/10.37358/RC.18.10.6640

Mihaela Buleandra, Anton Alexandru Ciucu, Dragos Cristian Stefanescu

Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation

Abstract:

A novel voltammetric assay for captopril (CAP) determination by using an electrochemically pretreated pencil graphite electrode (PGE*) is presented. The electrochemical oxidation reaction of CAP was investigated with PGE* by using cyclic voltammetry and linear sweep voltammetry techniques. CAP was electrochemically inactive at the non-pretreated pencil graphite electrode surface, while a sharp anodic wave with an anodic peak potential at around 200 mV resulted by using the PGE*. According to kinetic studies upon the electrode behavior, a new reaction mechanism for electrochemical oxidation of captopril is proposed. The sensor was examined as a selective, simple and precise new electrochemical disposable electrode for the determination of CAP in pharmaceutical samples in complex medical cases associated with sleep apnea, with good results.
Keywords:
isposable sensor; dopamine; voltammetry; pharmaceutical samples; sleep apnea

Issue: 2018, Volume 69, Issue 10
Pages: 2858-2862
Publication date: 2018/11/15
https://doi.org/10.37358/RC.18.10.6640
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
BULEANDRA, M., CIUCU, A.A., STEFANESCU, D.C., Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation, Rev. Chim., 69(10), 2018, 2858-2862.

Vancouver
Buleandra M, Ciucu AA, Stefanescu DC. Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation. Rev. Chim.[internet]. 2018 Oct;69(10):2858-2862. Available from: https://doi.org/10.37358/RC.18.10.6640


APA 6th edition
Buleandra, M., Ciucu, A.A. & Stefanescu, D.C. (2018). Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation. Revista de Chimie, 69(10), 2858-2862. https://doi.org/10.37358/RC.18.10.6640


Harvard
Buleandra, M., Ciucu, A.A., Stefanescu, D.C. (2018). 'Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation', Revista de Chimie, 69(10), pp. 2858-2862. https://doi.org/10.37358/RC.18.10.6640


IEEE
M. Buleandra, A.A. Ciucu, D.C. Stefanescu, "Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation". Revista de Chimie, vol. 69, no. 10, pp. 2858-2862, 2018. [online]. https://doi.org/10.37358/RC.18.10.6640


Text
Mihaela Buleandra, Anton Alexandru Ciucu, Dragos Cristian Stefanescu,
Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation,
Revista de Chimie,
Volume 69, Issue 10,
2018,
Pages 2858-2862,
ISSN 2668-8212,
https://doi.org/10.37358/RC.18.10.6640.
(https://revistadechimie.ro/Articles.asp?ID=6640)
Keywords: isposable sensor; dopamine; voltammetry; pharmaceutical samples; sleep apnea


RIS
TY - JOUR
T1 - Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation
A1 - Buleandra, Mihaela
A2 - Ciucu, Anton Alexandru
A3 - Stefanescu, Dragos Cristian
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2018
VL - 69
IS - 10
SP - 2858
EP - 2862
UR - https://doi.org/10.37358/RC.18.10.6640
KW - isposable sensor
KW - dopamine
KW - voltammetry
KW - pharmaceutical samples
KW - sleep apnea
ER -


BibTex
@article{RevCh2018P2858,
author = {Buleandra Mihaela and Ciucu Anton Alexandru and Stefanescu Dragos Cristian},
title = {Simple Real-time Voltammetric Method for Captopril Determination
in Pharmaceutical Formulation},
journal = {Revista de Chimie},
volume = {69},
number = {10},
pages = {2858-2862},
year = {2018},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.18.10.6640},
url = {https://revistadechimie.ro/Articles.asp?ID=6640}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice