ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2019, Volume 70, Issue 6, 2132-2135

https://doi.org/10.37358/RC.19.6.7290

Nicolae Baran, Mihaela Constantin, Beatrice Tanase, Edgar Moraru, Corina Ioana Moga

Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water

Abstract:

The paper presents two constructive solutions in the field of fine bubble generators that serve to aerate the water. Two installations for experimental researches have been designed and built in connection with the two constructive solutions. The dissolved oxygen concentration was experimentally determined. The theoretical and experimental results for the two constructive solutions are compared showing a good coincidence in relation to the results reported in the literature.
Keywords:
water aeration; fine bubbles generator; dissolved oxygen concentration

Issue: 2019, Volume 70, Issue 6
Pages: 2132-2135
Publication date: 2019/7/15
https://doi.org/10.37358/RC.19.6.7290
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
BARAN, N., CONSTANTIN, M., TANASE, B., MORARU, E., MOGA, C.I., Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water, Rev. Chim., 70(6), 2019, 2132-2135.

Vancouver
Baran N, Constantin M, Tanase B, Moraru E, Moga CI. Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water. Rev. Chim.[internet]. 2019 Jun;70(6):2132-2135. Available from: https://doi.org/10.37358/RC.19.6.7290


APA 6th edition
Baran, N., Constantin, M., Tanase, B., Moraru, E. & Moga, C.I. (2019). Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water. Revista de Chimie, 70(6), 2132-2135. https://doi.org/10.37358/RC.19.6.7290


Harvard
Baran, N., Constantin, M., Tanase, B., Moraru, E., Moga, C.I. (2019). 'Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water', Revista de Chimie, 70(6), pp. 2132-2135. https://doi.org/10.37358/RC.19.6.7290


IEEE
N. Baran, M. Constantin, B. Tanase, E. Moraru, C.I. Moga, "Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water". Revista de Chimie, vol. 70, no. 6, pp. 2132-2135, 2019. [online]. https://doi.org/10.37358/RC.19.6.7290


Text
Nicolae Baran, Mihaela Constantin, Beatrice Tanase, Edgar Moraru, Corina Ioana Moga,
Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water,
Revista de Chimie,
Volume 70, Issue 6,
2019,
Pages 2132-2135,
ISSN 2668-8212,
https://doi.org/10.37358/RC.19.6.7290.
(https://revistadechimie.ro/Articles.asp?ID=7290)
Keywords: water aeration; fine bubbles generator; dissolved oxygen concentration


RIS
TY - JOUR
T1 - Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water
A1 - Baran, Nicolae
A2 - Constantin, Mihaela
A3 - Tanase, Beatrice
A4 - Moraru, Edgar
A5 - Moga, Corina Ioana
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2019
VL - 70
IS - 6
SP - 2132
EP - 2135
UR - https://doi.org/10.37358/RC.19.6.7290
KW - water aeration; fine bubbles generator; dissolved oxygen concentration
ER -


BibTex
@article{RevCh2019P2132,
author = {Baran Nicolae and Constantin Mihaela and Tanase Beatrice and Moraru Edgar and Moga Corina Ioana},
title = {Influence of Fine Bubble Generator Architecture on Time Variation of Dissolved Oxygen Concentration in Water},
journal = {Revista de Chimie},
volume = {70},
number = {6},
pages = {2132-2135},
year = {2019},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.19.6.7290},
url = {https://revistadechimie.ro/Articles.asp?ID=7290}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice