ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2009, Volume 60, Issue 1,





Effect of pH on the Behaviour of Some Titanium
Alloys with Biphasic Structure

Abstract:

In this paper, the thermal and plastic deformation treatments were applied to Ti6Al4V alloy and its behaviour in Ringer 2 solution of different pH values (2.49; 6.9; 8.91), simulating the hardest conditions that can appear in human body, on the life time of an implant (10-20 years or more) was studied. The behaviour of the untreated Ti6Al4V ELI alloy and its five types of thermal-mechanical treated alloys was estimated from the corrosion rates, ion release, variation in time (500 hours) of the open circuit potentials Eoc and of the potential gradients DEoc(pH) due to the pH non-uniformity of Ringer 2 solution. Very low corrosion rates in the “perfect stable” or “very stable” range were determined. Ion release revealed very low values under permitted limits, therefore much reduced citotoxic effects. The open circuit potentials were ennobled at the beginning, then slowly decreased, tending to about constant values, showing the existence of the passive films on the studied material surfaces and of some dissolution, repassivation and absorption processes and their tendency to become stable. Open circuit potential values are more electropositive than those of titanium, so, more stable, more resistant films due to the both passivation effects of the alloying elements and the stability effect induced by the thermo -mechanical treatments. Potential gradients due to the pH nonuniformity of the Ringer solution have low values that can not generate galvanic corrosion (for 500 exposure hours). Keywords: monitoring of open circuit potentials; Ringer 2 solution of different pH values; passive films

Issue: 2009, Volume 60, Issue 1
Pages:
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice