ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 76, 2025
   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2009, Volume 60, Issue 4,





CODRUTA COFAN, CIPRIAN RADOVAN, DAN CINGHITA
Simultaneous Anodic Assessment of Ascorbic Acid
and Acetaminophen in Unbuffered Solutions


Abstract:

The simultaneous detection of L-ascorbic acid (AA) and acetaminophen (AC) at a boron-doped diamond electrode (BDDE), in a sodium sulphate supporting electrolyte, using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) was investigated. The calibration plots resulting from two distinct series of anodic current peaks versus concentration of AA and AC in single and di-component systems, obtained from CV and DPV data, presented linearity, with very good correlation coefficients. Fouling of the electrode surface was not evident and BDDE showed very reproducible voltammetric signals in all investigated situations. The relative standard deviations of 2 -3 %, high sensitivity values, and low limits of detection evaluated from DPV data in single systems, have been practically recovered in di-component standard and real sample solutions. The anodic assessment with the use of DPV was additionally verified by the simultaneous determination of AA and AC in real samples prepared from pharmaceutical products. Using a very simple supporting electrolyte, neutral unbuffered sodium sulphate solution, the DPV at a BDDE was confirmed as an easily applicable electroanalytical option. Individual and average values corresponding to AA and AC content in an investigated pharmaceutical product were determined by DPV coupled with standard addition method giving results in good accordance with the composition indicated by the supplier. Keywords: acetaminophen, ascorbic acid, differential pulse voltammetry, unbuffered media, boron-doped diamond electrode

Issue: 2009, Volume 60, Issue 4
Pages:
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice