ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 77, 2026
   Volume 76, 2025
   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2014, Volume 65, Issue 7,





VIOLETA-MONICA RADU, ELENA DIACU, ALEXANDRU ANTON IVANOV, DEAK GYÖRGY
Gas-Chromatographic Technique for the Analysis
of Flocculant PRAESTOL Content in Surface Waters

Abstract:

The increasing amount of relatively new industrial reagents used is of concern especially when the full environmental fate of these chemical compounds is insufficiently documented. For some of these new reagents, the lack of analysis methods creates difficulties in the water quality monitoring of the discharged effluents.This paper covers the development and optimization of an analysis method for the Praestol A3040L content in water samples. Praestol A3040L is a moderately anionic polyelectrolyte containing acrylamide - sodium acrylate copolymers, ethoxylated alcohols and hydrotreated light petroleum distillates as an aqueous emulsion and it is industrially used in water treatment installations to promote the settling of suspended particles. Based on the reagent known constituents the method uses as analytical signal the GC-FID detection and quantification of its non-polar hydrocarbons, separated from the water sample by liquid-liquid extraction. The GC method optimization was primary focused at achieving adequate repeatability and detection limits and not for the individual chemical species separation, the method using the combined signal generated by the complex organic fraction. The best results were achieved with an injector temperature of 375 °C in split-splitless mode, a N2, H2 and air flow rate of 25 mL/min, 30 mL/min and 300 mL/min, a ratio of air:H2 of 10:1, a carrier gas flow rate of 2 mL/min with an initial column temperature of 50 °C, followed by an increase with 20 °C /min up to 360 °C and a detector temperature of 360 °C. The method has a detection limit of 0.005 mg/L, a quantification limit of 0.01 mg/L with a repeatability of approximately 20 % and a linear calibration range up to 5 mg/L with a linearity coefficient of 0.997 (all concentrations being express as A3040L mass per aqueous sample volume). Keywords: gas chromatography, PRAESTOL A3040 L, water treatment

Issue: 2014, Volume 65, Issue 7
Pages:
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice