ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHORS'S SUBSCRIPTIONS AUTHORS'S PAGE PUBLISHING ETHICS NEWS, EVENTS
REVISTA DE CHIMIE
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN 0034-7752
ISSN 2668-8212 (Online)
Journal Metrics
* Impact Factor 2018-19: 1.605
* 5-Year IF: 1.34
* CiteScore: 1.23
* SNIP: 0.710
* SJR: 0.294
(academic-accelerator.com)
Crossref Member Badge
 DOI  logo

Chemistry Magazine

LATEST ISSUE >>>

   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
   Volume 57, 2006
   Volume 56, 2005
   Volume 55, 2004
   Volume 54, 2003
   Volume 53, 2002
 
<<<< back

Revista de Chimie, Volume 66, Issue 1, pp. (2015)




ADELA MEGHESAN - BREJA, CONSTANTIN MARUTOIU, CLAUDIA CIMPOIU Multi-residues Analysis for 88 Pesticides and Metabolites from Soil by Gas Chromatography-time - of - Flight Mass Spectrometry

Abstract:

An easy and fast Gas Chromatography-time-of-Flight Mass Spectrometry (GC-TOF-MS) method for 88 pesticides and metabolites identification and quantitation from soil was developed. Most widely used pesticides from group of pesticides, like herbicide, insecticide, fungicide were analyzed. The soil samples were extracted with acetonitrile acidified with 1% acetic acid; then extract was buffered with anhydrous magnesium sulfate and sodium acetate and then was cleaned-up by solid-phase extraction (SPE) with anhydrous magnesium sulfate and primary-secondary amine (PSA) . The final extract was directly injected in GC. Analysis of extracts was carried out by GC-TOF-MS within 29.2min run time. The GC method was validated for soil in term of linearity, accuracy, limit of detection (LOD) and limit of quantification (LOQ). Good linearity with correlation coefficients (r2) higher than 0.98 was obtained. For 60 analytes recoveries were in range of 70-120% and LOQ values in range of 0.01- 0.05mg/kg. Instrument LOD values generally varied from 0.5 to 0.8ng . mL-1. The developed method was successfully tested on five soil samples from different cultivated lands, with and without known history in terms of pesticide use. Keywords: Soil; Pesticide residues; Multi-residues analysis; Gas chromatography-Time-of-flight Mass Spectrometry, Solid-phase extraction

Issue: 2015 Volume 66, Number 1
Pages:
download pdf   Download Pdf Article
 
Views number: 235    |     Downloads number: 26  
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Ghidul Autorului (ro)
 * Paper Drafting
 * Paper Template
 * Paper Submission
 * Author Payments
 * Publishing Ethics
Submit Paper
Author's Page
  News, Events
 chimie
*REVISTA DE CHIMIE - 70 de ani de aparitie neintrerupta*

Un eveniment special pentru comunitatea stiintifica din Romania va fi organizat in data de
4 martie 2020
Hotel Hilton Athenee Palace Bucuresti
Sala Regina Maria
ora 9.30.

Va asteptam.
 Chemistry Conferences Conferences of Contemporary Chemistry
 Publicatii de Chimie Publicatii de Chimie in Romania.
Scurt istoric
 BIBLIOTECA CHIMIEI Biblioteca Chimiei
 Materiale Plastice Materiale Plastice