ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 77, 2026
   Volume 76, 2025
   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2016, Volume 67, Issue 3,



Stefania Corina Mahu, Adrian Florin Spac, Constantin Ciobanu, Monica Hancianu, Luminita Agoroaei, Elena Butnaru

Quantitative Determination of Bisoprolol Fumarate by HPLC. I. Method validation

Abstract:

Bisoprolol belongs to the selective beta-blockers class, initially used for the treatment of cardiac arrhythmias and later in patients with arterial hypertension. A simple and accurate method of high performance liquid chromatography (HPLC) was developed and validated for the determination of bisoprolol fumarate in tablets. The chromatographic analysis was performed using an Eclipse XDB C18 type column (150 mm x 4.6 mm, 5 m) with a mobile phase consisting of a mixture of water / methanol / acetonitrile in a ratio of 50:30:20 (v/v/v). The mobile phase flow rate was 1 mL/min, UV detection being carried out at a wavelength of 225 nm. The injected volume was 20 mL. The temperature of the column compartment was kept constant at 250 C. The HPLC method for the determination of bisoprolol shows two areas of linearity in the range of 0.8 - 80 g/mL and 80 - 1000 g/mL, respectively. Limit of detection for bisoprolol fumarate was 1.3 g/mL and limit of quantification was 3.98 g/mL.The developed method was appropriately validated for linearity, limit of detection, limit of quantification, precision and accuracy in accordance with the international guidelines. The proposed method proved to be simple, precise, and accurate, and can be successfully applied for the determination of bisoprolol in tablets.
Keywords:
bisoprolol fumarate; HPLC; multidiode detector; validation

Issue: 2016, Volume 67, Issue 3
Pages:
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice