ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2016, Volume 67, Issue 11,





Raluca Senin, Virgil Badescu, RusAndica Stoica
Polychlorinated Biphenyl Compounds (PCBs) Determination
from Water by Gas Chromatography Coupled
with Mass Spectrometry (GC-MS)

Abstract:

Because they are not biodegradable, PCBs contribute to irreversible environmental pollution, and by ingestion, accumulate in adipose tissue, contributing to endocrine disrupters. By reason of these problems, it is necessary to improve the sensitivity and speed of PCB monitoring technology. In general, PCB is analyzed by gas chromatography with electron capture detector (GC-ECD) using classical columns with packed or capillary columns. These conventional analytical techniques, however, have accuracy problems in PCB detection that can occur due to interference owing to the matrix. The detection method by mass spectrometry, in the variant Selected Ion Monitoring contributes to the elimination of some interference between PCBs and some chemical compounds from the matrix, remained after the separation step. It chased the development of an analytical method for PCBs determination in water matrix by gas chromatography on fussed capillary column coupled with quadrupole mass spectrometry. As the method has been developed in laboratory, the method validation has been necessary studying the following performance parameters: specificity, selectivity, repeatability, intermediary precision, recovery, detection limit and robustness. The development of GC-MS method for PCBs determination in water consisted in establishing of the separation conditions of the analyzed components from water matrix (at an adequate recovery), by liquid-liquid extraction, the establishing of the optimal GC-MS parameters and the validation of this method. In the step of the analytes-matrix separation, PCBs from water samples prepared for analysis was extracted with hexane, carbon disulfide and chloroform through stirring at an appropriate speed followed by separating funnel separation. The organic fractions were concentrated to a final volume of 10 mL at a constant vacuum, with a Kuderna-Denish evaporator for GC-MS analysis. In the step II were established the optimal GC-MS separation parameters. The detection and quantitative determination by mass spectrometry, in the variant Selected Ion Monitoring”(MS-SIR) was used. In order to determine the PCBs recovery of the samples, three series of standards of the PCBs 28, 52, 101, 138, 153, 180 of 10 ppb in the solution to be analyzed using as extraction solvent hexane, carbon disulfide and chloroform were used. Recovery levels obtained were between 50% and 117% for hexane, 37 - 127 % for carbon disulfide and 65-111 % for chloroform. The selectivity, determined as lack of interferences with the compounds of interest, was achieved through the repeatability of the gas chromatographic retention times and by quantification ion and qualifying ions from MS-SIR method. This improved selectivity eliminates interferences between PCBs and some chemical compounds in water matrix remaining after liquid-liquid extraction step and incomplete gas chromatographic separation.The GC-MS-SIR method performs an adequate separation of PCBs from the water matrix and eliminates some extractible interfering elements with a recovery of 50-120 % and determines the PCBs in the concentration range of 1-100 pg/mL PCB in water (1-100 ng/mL in the solution to be analyzed Keywords: PCBs, environmental pollution, GC-MS

Issue: 2016, Volume 67, Issue 11
Pages:
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice