Revista de Chimie (Rev. Chim.), Year 2017, Volume 68, Issue 9, 2114-2116

https://doi.org/10.37358/RC.17.9.5835

Corneliu Rontescu, Dumitru Titi Cicic, Catalin Gheorghe Amza, Oana Roxana Chivu, Gabriel Iacobescu

Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments

Abstract:

This paper presents a comparative study on the microstructural and mechanical characteristics of a biocompatible titanium and Co-Cr alloys used in prosthetics implants and medical instruments fabrications. The samples used for the analysis were obtained by applying the additive manufacturing process called Direct Melting Laser Sintering. Following the analysis of the results obtained for the two sets of samples it was observed that the thermophysical properties of the materials influence the quality of the obtained surfaces.
Keywords:
prostheses; medical instruments; titanium alloys; Co-Cr alloys; DMLS

Issue: 2017, Volume 68, Issue 9
Pages: 2114-2116
Publication date: 2017/10/15
https://doi.org/10.37358/RC.17.9.5835
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
RONTESCU, C., CICIC, D.T., AMZA, C.G., CHIVU, O.R., IACOBESCU, G., Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments, Rev. Chim., 68(9), 2017, 2114-2116.

Vancouver
Rontescu C, Cicic DT, Amza CG, Chivu OR, Iacobescu G. Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments. Rev. Chim.[internet]. 2017 Sep;68(9):2114-2116. Available from: https://doi.org/10.37358/RC.17.9.5835


APA 6th edition
Rontescu, C., Cicic, D.T., Amza, C.G., Chivu, O.R. & Iacobescu, G. (2017). Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments. Revista de Chimie, 68(9), 2114-2116. https://doi.org/10.37358/RC.17.9.5835


Harvard
Rontescu, C., Cicic, D.T., Amza, C.G., Chivu, O.R., Iacobescu, G. (2017). 'Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments', Revista de Chimie, 68(9), pp. 2114-2116. https://doi.org/10.37358/RC.17.9.5835


IEEE
C. Rontescu, D.T. Cicic, C.G. Amza, O.R. Chivu, G. Iacobescu, "Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments". Revista de Chimie, vol. 68, no. 9, pp. 2114-2116, 2017. [online]. https://doi.org/10.37358/RC.17.9.5835


Text
Corneliu Rontescu, Dumitru Titi Cicic, Catalin Gheorghe Amza, Oana Roxana Chivu, Gabriel Iacobescu,
Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments,
Revista de Chimie,
Volume 68, Issue 9,
2017,
Pages 2114-2116,
ISSN 2668-8212,
https://doi.org/10.37358/RC.17.9.5835.
(https://revistadechimie.ro/Articles.asp?ID=5835)
Keywords: prostheses; medical instruments; titanium alloys; Co-Cr alloys; DMLS


RIS
TY - JOUR
T1 - Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments
A1 - Rontescu, Corneliu
A2 - Cicic, Dumitru Titi
A3 - Amza, Catalin Gheorghe
A4 - Chivu, Oana Roxana
A5 - Iacobescu, Gabriel
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2017
VL - 68
IS - 9
SP - 2114
EP - 2116
UR - https://doi.org/10.37358/RC.17.9.5835
KW - prostheses
KW - medical instruments
KW - titanium alloys
KW - Co-Cr alloys
KW - DMLS
ER -


BibTex
@article{RevCh2017P2114,
author = {Rontescu Corneliu and Cicic Dumitru Titi and Amza Catalin Gheorghe and Chivu Oana Roxana and Iacobescu Gabriel},
title = {Comparative Analysis of the Components Obtained by Additive Manufacturing Used for Prosthetics and Medical Instruments},
journal = {Revista de Chimie},
volume = {68},
number = {9},
pages = {2114-2116},
year = {2017},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.17.9.5835},
url = {https://revistadechimie.ro/Articles.asp?ID=5835}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice