Elena Bucur, Radu Motisan, Andrei Vasile, Gheorghita Tanase, Luoana Florentina Pascu, Carol Blaziu Lehr, Adriana Cuciureanu
Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air
Abstract:
The paper presents the test results regarding the evaluation of the accuracy of the PM2.5 and PM10 particulate matter concentration measurement performed with the uRADMonitor A3 fixed air quality monitoring station produced by SC MAGNASCI SRL. The procedure involves the calculation of the accuracy elements: trueness and precision, based on the experimental data obtained by measuring the concentration of particulate matter using the tested analysers in parallel with the reference method, SR EN 12341: 2014, and analysis of data series by Pearson correlation and linear regression.
Keywords: accuracy; ambient air; Pearson correlation; PM2.5 and PM10
Cite this article as: BUCUR, E., MOTISAN, R., VASILE, A., TANASE, G., PASCU, L.F., LEHR, C.B., CUCIUREANU, A., Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air, Rev. Chim., 71(1), 2020, 83-87.
Vancouver Bucur E, Motisan R, Vasile A, Tanase G, Pascu LF, Lehr CB, Cuciureanu A. Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air. Rev. Chim.[internet]. 2020 Jan;71(1):83-87. Available from: https://doi.org/10.37358/RC.20.1.7816
APA 6th edition Bucur, E., Motisan, R., Vasile, A., Tanase, G., Pascu, L.F., Lehr, C.B. & Cuciureanu, A. (2020). Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air. Revista de Chimie, 71(1), 83-87. https://doi.org/10.37358/RC.20.1.7816
Harvard Bucur, E., Motisan, R., Vasile, A., Tanase, G., Pascu, L.F., Lehr, C.B., Cuciureanu, A. (2020). 'Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air', Revista de Chimie, 71(1), pp. 83-87. https://doi.org/10.37358/RC.20.1.7816
IEEE E. Bucur, R. Motisan, A. Vasile, G. Tanase, L.F. Pascu, C.B. Lehr, A. Cuciureanu, "Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air". Revista de Chimie, vol. 71, no. 1, pp. 83-87, 2020. [online]. https://doi.org/10.37358/RC.20.1.7816
Text Elena Bucur, Radu Motisan, Andrei Vasile, Gheorghita Tanase, Luoana Florentina Pascu, Carol Blaziu Lehr, Adriana Cuciureanu, Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air, Revista de Chimie, Volume 71, Issue 1, 2020, Pages 83-87, ISSN 2668-8212, https://doi.org/10.37358/RC.20.1.7816. (https://revistadechimie.ro/Articles.asp?ID=7816) Keywords: accuracy; ambient air; Pearson correlation; PM2.5 and PM10
RIS TY - JOUR T1 - Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air A1 - Bucur, Elena A2 - Motisan, Radu A3 - Vasile, Andrei A4 - Tanase, Gheorghita A5 - Pascu, Luoana Florentina A6 - Lehr, Carol Blaziu A7 - Cuciureanu, Adriana JF - Revista de Chimie JO - Rev. Chim. PB - Revista de Chimie SRL SN - 2668-8212 Y1 - 2020 VL - 71 IS - 1 SP - 83 EP - 87 UR - https://doi.org/10.37358/RC.20.1.7816 KW - accuracy KW - ambient air KW - Pearson correlation KW - PM2.5 and PM10 ER -
BibTex @article{RevCh2020P83, author = {Bucur Elena and Motisan Radu and Vasile Andrei and Tanase Gheorghita and Pascu Luoana Florentina and Lehr Carol Blaziu and Cuciureanu Adriana}, title = {Assessment of the Accuracy of Analyzers for Automatic Determination of PM10 and PM2.5 Particulate Matter in Ambient Air}, journal = {Revista de Chimie}, volume = {71}, number = {1}, pages = {83-87}, year = {2020}, issn = {2668-8212}, doi = {https://doi.org/10.37358/RC.20.1.7816}, url = {https://revistadechimie.ro/Articles.asp?ID=7816} }