ABOUT INDEXING BOARD ARCHIVES AUTHOR GUIDELINES SUBMIT PAPER AUTHOR'S PAGE NEWS, EVENTS CONTACT
REVISTA DE CHIMIE
Cite as: Rev. Chim.
https://doi.org/10.37358/Rev.Chim.1949

OSIM Nr. R102355
ISSN Online 2668-8212
ISSN Print: 1582-9049
ISSN-L: 1582-9049

REVISTA DE CHIMIE Latest Issue

LATEST ISSUE >>>

   Volume 75, 2024
   Volume 74, 2023
   Volume 73, 2022
   Volume 72, 2021
   Volume 71, 2020
   Volume 70, 2019
   Volume 69, 2018
   Volume 68, 2017
   Volume 67, 2016
   Volume 66, 2015
   Volume 65, 2014
   Volume 64, 2013
   Volume 63, 2012
   Volume 62, 2011
   Volume 61, 2010
   Volume 60, 2009
   Volume 59, 2008
   Volume 58, 2007
 
<<<< back

Revista de Chimie (Rev. Chim.), Year 2020, Volume 71, Issue 2, 209-217

https://doi.org/10.37358/RC.20.2.7918

Virgil Badescu

Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements

Abstract:

The aim of this article in continuation of Parts I [1] and II [2] is the interpretation of the TEOS mass spectrum as a precursor in the sol-gel process. In Part I [1] the primary fragmentation ions at masses 207, 193, 179 and 163 were obtained experimentally by B/E linked scan by radical induced fragmentation reactions. In Part II [2] eliminations of neutral fragments from the primary ions and the obtained ions by consecutive elimination reactions were evidenced experimentally by the B/E and B/E(1-E)1/2 linked scans. In this third and final Part of interpretation of the TEOS mass spectrum, the separation of ions by mass spectrometry at high resolutions of 5000 and 6600, relative to standard resolution 1000, and measurements of the M+1 and M+2 isotopic effects at the resolution of 5000 are presented. The separation of the ions with nominal mass 105 at high resolution is detailed.
Keywords:
tetraethoxysilane; mass spectrum; accurate mass; M+1; M+2 isotopic effects

Issue: 2020, Volume 71, Issue 2
Pages: 209-217
Publication date: 2020/3/3
https://doi.org/10.37358/RC.20.2.7918
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
BADESCU, V., Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements, Rev. Chim., 71(2), 2020, 209-217.

Vancouver
Badescu V. Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements. Rev. Chim.[internet]. 2020 Feb;71(2):209-217. Available from: https://doi.org/10.37358/RC.20.2.7918


APA 6th edition
Badescu, V., (2020). Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements. Revista de Chimie, 71(2), 209-217. https://doi.org/10.37358/RC.20.2.7918


Harvard
Badescu, V., (2020). 'Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements', Revista de Chimie, 71(2), pp. 209-217. https://doi.org/10.37358/RC.20.2.7918


IEEE
V. Badescu, "Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements". Revista de Chimie, vol. 71, no. 2, pp. 209-217, 2020. [online]. https://doi.org/10.37358/RC.20.2.7918


Text
Virgil Badescu,
Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements,
Revista de Chimie,
Volume 71, Issue 2,
2020,
Pages 209-217,
ISSN 2668-8212,
https://doi.org/10.37358/RC.20.2.7918.
(https://revistadechimie.ro/Articles.asp?ID=7918)
Keywords: tetraethoxysilane; mass spectrum; accurate mass; M+1; M+2 isotopic effects


RIS
TY - JOUR
T1 - Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements
A1 - Badescu, Virgil
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2020
VL - 71
IS - 2
SP - 209
EP - 217
UR - https://doi.org/10.37358/RC.20.2.7918
KW - tetraethoxysilane
KW - mass spectrum
KW - accurate mass
KW - M+1
KW - M+2 isotopic effects
ER -


BibTex
@article{RevCh2020P209,
author = {Badescu Virgil},
title = {Contributions to the Interpretation of Mass Spectrum of Tetraethoxysilane (TEOS). III. Accurate mass and M+1, M+2 isotopic effect measurements},
journal = {Revista de Chimie},
volume = {71},
number = {2},
pages = {209-217},
year = {2020},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.20.2.7918},
url = {https://revistadechimie.ro/Articles.asp?ID=7918}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice