Revista de Chimie (Rev. Chim.), Year 2020, Volume 71, Issue 6, 96-110

https://doi.org/10.37358/RC.20.6.8175

Omyma Ramadan Mohammed Khalifa, Abdel-Wahab Abd Elhamid Ali, Aisha Kassab, Amal Hemida Tilp, Marwa Mohamed Mohamed Mohamed Esmail

Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant

Abstract:

In recent years, smart implants take the most attention in the field of bone manufacturing. Our study seeks to develop the biodegradability of Mg alloys to use orthopedic implants for the biomedical applications to avoid post removal of the implant. Mg and Zn are very important to human body and have no toxicity. Mg - 6% wt Zn biodegradability is studied in simulated body fluid for two and four weeks. Four electro-deposition bathes are used to deposit a coat on the substrate to improve the corrosion resistance of this alloy in the media of simulated body fluid. The following analyses were studied to emphasize the research aim. Scanning electron microscope (SEM), Energy dispersive X-Ray (EDX) analysis shows the surface morphology and the elements of the coat phases components. The results also confirmed by X-Ray diffraction Pattern (XRD) that show the phases that confirmed the formation of hydroxyapatite HA phase, Fourier-Transform Infrared Spectroscopy (FTIR) to investigate the functional groups of the phases coats that confirm the formation of hydroxyapatite and the electrochemical measurements that investigate the improvement of corrosion resistance. The results indicated that the fourth bath gives the best coat and four weeks immersion gives more corrosion resistance than two weeks.
Keywords:
Smart implant; Mg-6%Zn; hydroxyapatite; Electro-deposition bathes; Corrosion resistance

Issue: 2020, Volume 71, Issue 6
Pages: 96-110
Publication date: 2020/7/1
https://doi.org/10.37358/RC.20.6.8175
download pdf   Download Pdf Article
Creative Commons License
This article is published under the Creative Commons Attribution 4.0 International License
Citation Styles
Cite this article as:
KHALIFA, O.R.M., ALI, A.A.E., KASSAB, A., TILP, A.H., ESMAIL, M.M.M.M., Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant, Rev. Chim., 71(6), 2020, 96-110.

Vancouver
Khalifa ORM, Ali AAE, Kassab A, Tilp AH, Esmail MMMM. Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant. Rev. Chim.[internet]. 2020 Jun;71(6):96-110. Available from: https://doi.org/10.37358/RC.20.6.8175


APA 6th edition
Khalifa, O.R.M., Ali, A.A.E., Kassab, A., Tilp, A.H. & Esmail, M.M.M.M. (2020). Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant. Revista de Chimie, 71(6), 96-110. https://doi.org/10.37358/RC.20.6.8175


Harvard
Khalifa, O.R.M., Ali, A.A.E., Kassab, A., Tilp, A.H., Esmail, M.M.M.M. (2020). 'Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant', Revista de Chimie, 71(6), pp. 96-110. https://doi.org/10.37358/RC.20.6.8175


IEEE
O.R.M. Khalifa, A.A.E. Ali, A. Kassab, A.H. Tilp, M.M.M.M. Esmail, "Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant". Revista de Chimie, vol. 71, no. 6, pp. 96-110, 2020. [online]. https://doi.org/10.37358/RC.20.6.8175


Text
Omyma Ramadan Mohammed Khalifa, Abdel-Wahab Abd Elhamid Ali, Aisha Kassab, Amal Hemida Tilp, Marwa Mohamed Mohamed Mohamed Esmail,
Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant,
Revista de Chimie,
Volume 71, Issue 6,
2020,
Pages 96-110,
ISSN 2668-8212,
https://doi.org/10.37358/RC.20.6.8175.
(https://revistadechimie.ro/Articles.asp?ID=8175)
Keywords: Smart implant; Mg-6%Zn; hydroxyapatite; Electro-deposition bathes; Corrosion resistance


RIS
TY - JOUR
T1 - Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant
A1 - Khalifa, Omyma Ramadan Mohammed
A2 - Ali, Abdel-Wahab Abd Elhamid
A3 - Kassab, Aisha
A4 - Tilp, Amal Hemida
A5 - Esmail, Marwa Mohamed Mohamed Mohamed
JF - Revista de Chimie
JO - Rev. Chim.
PB - Revista de Chimie SRL
SN - 2668-8212
Y1 - 2020
VL - 71
IS - 6
SP - 96
EP - 110
UR - https://doi.org/10.37358/RC.20.6.8175
KW - Smart implant
KW - Mg-6%Zn
KW - hydroxyapatite
KW - Electro-deposition bathes
KW - Corrosion resistance
ER -


BibTex
@article{RevCh2020P96,
author = {Khalifa Omyma Ramadan Mohammed and Ali Abdel-Wahab Abd Elhamid and Kassab Aisha and Tilp Amal Hemida and Esmail Marwa Mohamed Mohamed Mohamed},
title = {Effect of Zn Content on Orthopedic Mg aAlloy as Smart Implant},
journal = {Revista de Chimie},
volume = {71},
number = {6},
pages = {96-110},
year = {2020},
issn = {2668-8212},
doi = {https://doi.org/10.37358/RC.20.6.8175},
url = {https://revistadechimie.ro/Articles.asp?ID=8175}
}
 
<<<< back
 
PUBLISHING SECTION
Author Guidelines
 * Paper Drafting
 * Paper Template
 * Ethical Statement
 * Paper Submission
Ghidul Autorului (ro)
Submit Paper
Author's Page
Publishing Ethics
Peer Review Process
Open Access & Archiving Policy
 Search Authors
 LATEST NEWS
REvista de Chimie NUMAR OMAGIAL PETRU PONI.. detalii
REvista de Chimie Revista de Chimie - 70 de ani de aparitie neintrerupta.. detalii
dictionar English-Romanian Dictionary for Mechanical Engineering
(download pdf)
  News, Events
Crossref Member Badge
 DOI  logo
 Gold Open Access | Source=http://www.plos.org/  | Author=art designer at PLoS
Creative Commons License
 Conferences of Contemporary
 Chemistry
 Biblioteca Chimiei
 Materiale Plastice